+86-571-88550927
 
Bimetal Thermometer
 

Wide portfolio
Kev ntsuas siab raug thiab lub neej ua haujlwm ntev
Tsawg susceptibility rau kev cuam tshuam, thiab yog li cov txheej txheem siab ntseeg tau

Hauv kev ntsuas kub, feem ntau, peb hom dial thermometers yog siv: bimetal thermometers, gas-actuated thermometers, thiab expansion thermometers. Kev ntsuas lub hauv paus ntsiab lus twg yuav tsum tau siv nyob ntawm ntau yam sib txawv, xws li lub sijhawm teb, qhov ntsuas kub thiab kev siv ntau yam.

Tus pas ntsuas kub bimetal yog dab tsi thiab tus pas ntsuas kub bimetal ntsuas li cas?
 

Bimetal thermometers yog cov ntsuas ntsuas kub raws li lub hauv paus ntsiab lus uas cov hlau nthuav dav txawv nyob ntawm qhov ntsuas kub. Tus pas ntsuas kub bimetal ib txwm muaj ob txoj hlua hlau sib txawv uas muaj qhov sib txawv thermal expansion coefficient. Ob lub strips yog sib koom ua ke inseparably thiab yog li tsim cov bimetal sawb. Thaum qhov kub hloov pauv, cov hlau sib txawv nthuav dav mus rau qhov sib txawv, uas ua rau lub tshuab deformation ntawm bimetal sawb. Qhov no mechanical deformation tuaj yeem kuaj pom nyob rau hauv lub zog teb. Lub ntsuas ntsuas ua haujlwm nyob rau hauv daim ntawv ntawm helical lossis kauv raj. Qhov kev txav no yog xa mus rau tus pointer ntawm tus pas ntsuas kub ntawm lub pointer ncej, uas yog li ua kom ntsuas qhov ntsuas kub.

Cov ntawv thov twg yog siv cov ntsuas kub bimetal?

Bimetal thermometers yog siv nyob rau hauv ntau yam kev lag luam siv, xws li hauv tshuab tsev, cua sov tshuab, thiab cua txias thiab tub yees tshuab. Ntau hom qauv bimetallic thermometers muaj ntau yam kev xaiv ntawm cov ntsuas kub hauv ntau hom kev siv.

Tus qauv 52 bimetallic tus pas ntsuas kub, nrog nws cov ntaub ntawv thiab qia ua los ntawm cov hlau tsis muaj steel, sawv cev rau cov qauv nkag ntawm cov txheej txheem ntsuas kub tab sis kuj yog siv rau kev thov hauv kev siv tshuab.

Tus qauv A48 bimetal tus pas ntsuas kub tau tsim tshwj xeeb rau kev siv hauv tshuab cua txias thiab tub yees los ntsuas qhov ntsuas kub hauv cov pa cua, hos tus qauv A43 bimetal tus pas ntsuas kub tau tsim los ua tus qauv qauv rau kev ntsuas kub yooj yim hauv tshuab cua sov. Raws li koj tuaj yeem pom, peb muab tus pas ntsuas kub haum rau txhua daim ntawv thov. Peb cov kws tshaj lij yuav zoo siab los qhia koj txog koj qhov kev xaiv.

Bimetal Thermometer Khoom Description

 

  • Lub kaum sab xis Adjustable Bimetal Thermometer
    Lub kaum sab xis Adjustable Bimetal Thermometer

    Lub kaum sab xis adjustable bimetal tus pas ntsuas kub. Kev tswj hwm tus qauv: rov pib dua thiab kho tau bimetal tus pas ntsuas kub dial gauge JB / T8803-1998; GB3836-83. Vaj huam sib luag

    Ntxiv rau Kev Nug
  • Bi-hlau Industrial Thermometer
    Bi-hlau Industrial Thermometer

    Bimetallic (Bimetal) Thermometer gauges yog txhim khu kev qha thiab raug ntsuas kub uas yuav tsum tsis muaj hluav taws xob lossis thaiv. Bimetal ntsuas kub ntsuas yog qhov zoo tagnrho rau hauv zos,

    Ntxiv rau Kev Nug
  • WSS -411 Bimetal Thermometer Nrog Hluav Taws Xob
    WSS -411 Bimetal Thermometer Nrog Hluav Taws Xob

    WSS-411 Bimetal tus pas ntsuas kub nrog hluav taws xob tiv tauj. Cov chav kawm raug: 1.5, khoom siv: stainless hlau. dial 60mm, sojntsuam ntev:50-2000mm. OEM muab kev pabcuam. hu rau Yucheng

    Ntxiv rau Kev Nug
  • Axial Hom Hluav Taws Xob Tiv Thaiv Qhov Ntsuas Kub
    Axial Hom Hluav Taws Xob Tiv Thaiv Qhov Ntsuas Kub

    Axial hom lossis Radial hom hluav taws xob tiv tauj bimetal thermomteer. Cov chav kawm raug: 1.5, khoom siv: stainless hlau. dial 60mm, sojntsuam ntev: 50-2000mm. OEM muab kev pabcuam. hu rau Yucheng

    Ntxiv rau Kev Nug
  • WSSX Electric Contact Bimetal Thermometer
    WSSX Electric Contact Bimetal Thermometer

    wss-381 hluav taws xob tiv tauj bimetal thermomteer. Cov chav kawm raug: 1.5, khoom siv: stainless hlau. Dial 100mm, sojntsuam ntev: 300mm. OEM muab kev pabcuam. hu rau Yucheng technology kom paub

    Ntxiv rau Kev Nug
  • SS Bimetal Thermometer ntsuas kub
    SS Bimetal Thermometer ntsuas kub

    SS Bimetal Thermometer ntsuas kub. Tsheb sib txuas bimetallic tus pas ntsuas kub ntsuas kub ntawm 0 mus rau +120 degree . Mount tus pas ntsuas kub nrog lub ntsuas cua kub uas muaj tus poj niam G 1/2

    Ntxiv rau Kev Nug
  • 200mm Bimetallic Thermometer Nrog Thermowell
    200mm Bimetallic Thermometer Nrog Thermowell

    200mm qia bimetallic tus pas ntsuas kub nrog thermowell. Tsheb sib txuas bimetallic tus pas ntsuas kub ntsuas kub ntawm 0 txog +120 ° C. Mount tus pas ntsuas kub nrog lub ntsuas cua kub uas muaj tus

    Ntxiv rau Kev Nug
  • 0 Rau +120°C Custom Bimetallic Thermometer
    0 Rau +120°C Custom Bimetallic Thermometer

    0 txog +120°C Custom Bimetallic Thermometer. Tsheb sib txuas bimetallic tus pas ntsuas kub ntsuas kub ntawm 0 txog +120 ° C. Mount tus pas ntsuas kub nrog lub ntsuas cua kub uas muaj tus poj niam G

    Ntxiv rau Kev Nug
  • Stainless hlau ntsuas kub ntsuas rau Industrial
    Stainless hlau ntsuas kub ntsuas rau Industrial

    Stainless hlau ntsuas kub ntsuas rau Industrial. Stainless hlau rooj plaub&qia ntev muaj los ntawm 50 hli hauv qab / rov qab / txhua lub kaum sab xis nkagSilicon roj ntim (yeem) Nrog lossis tsis muaj

    Ntxiv rau Kev Nug
Tsev 1234567 Rau sab kawg 1/9
Tuam txhab profile
 

Hangzhou Yucheng Science & Technology Co., Ltd yog lub chaw tsim khoom ntawm cov cuab yeej siv siab, peb lub Hoobkas tau tsim nyob rau xyoo 2005 thiab tshwj xeeb hauv kev tsim cov ntsuas kub, ntsuas kub, ntsuas, thiab lwm yam khoom siv.

Tag nrho peb cov cuab yeej siv siab tau siv dav hauv Cov Roj & Roj refinery, textiles, tshuaj, zaub mov, thiab dej haus kev lag luam.

ISO9001: 2000 lub tuam txhab muaj ntawv pov thawj, los lav cov khoom zoo heev.

Cov neeg siv khoom tseem ceeb los ntawm Africa, South America, North America, thiab Asia. thiab Europe.

Peb lub peev xwm ntau lawm: txog 1 lab teeb ntawm ntau yam khoom siv siab.

Peb qhov chaw: Hoobkas hauv Ningbo thiab Hangzhou, chaw ua haujlwm hauv Hangzhou.

Tiv tauj peb rau txhua qhov kev thov. peb yuav tsim thiab tsim cov khoom zoo raws li koj qhov kev thov ntawm tus nqi sib tw.

Hangzhou Yucheng Science Technology CoLtd

01

Siab Zoo

02

Khoom siv Advanced

03

Pab neeg tshaj lij

04

Kev Pabcuam Kev Cai

Dial Adjustment
Dial Kho
Oil Filling
Roj Sau
Static Pressure Test
Static Pressure Test
Packing
Ntim

Dab tsi yog qhov zoo thiab qhov tsis zoo ntawm bimetal thermometers?

 

 

Piv nrog rau cov ntsuas cua kub cua, bimetal thermometers yog pheej yig dua ntawm tus nqi. Qhov zoo ntawm tus nqi no yog vim lawv txoj kev tsim kho yooj yim.

 

Qhov ntsuas qhov ntsuas kub ntawm bimetal ntsuas yog nyob nruab nrab ntawm -70 thiab +600 degree (-94 thiab +1,112 degree F) nrog qhov raug cov chav kawm 1 thiab 2 los ntawm EN 13190. Rau cov ntawv thov hauv uas muaj kev vibrations siab, cov ntsuas kub nrog cov kua filling yog siv. Rau kev sau, cov roj silicone yog siv, uas ua rau cov kev vibration thiab txwv qhov kub siab tshaj plaws rau +250 degree (482 degree F).

 

Thaum qhov kub hloov pauv, txhua hom dial thermometers teb los ntawm tib txoj cai; txoj kev nthuav dav. Qhov txawv, txawm li cas los xij, yog tias nrog tus pas ntsuas kub bimetal, qhov txav txav ntawm bimetal tsuas tuaj yeem pom ncaj qha rau ntawm cov zaub. Nrog rau qhov ntsuas kub ntawm cov pa roj, ntawm qhov tod tes, ntsuas tus nqi tau yooj yim kis tau los ntawm capillary vim nws cov roj inert filling. Tej thaj chaw deb capillaries tuaj yeem siv tau ntawm no los teeb tsa cov ntsuas cua kub txog li 60 meters deb ntawm qhov ntsuas qhov chaw. Expansion thermometers kuj tuaj yeem ntsia tau ntawm cov chaw taws teeb capillaries, tab sis, es tsis txhob siv cov roj inert, ib qho nruab nrab filling yog siv rau kev ntsuas, xws li xylene lossis silicone roj.

 

Qhov kev txiav txim zaum kawg ntawm tus pas ntsuas kub uas siv tau nyob ntawm ntau yam sib txawv. Peb cov kws tshaj lij yuav zoo siab los qhia koj hauv kev xaiv lub ntsuas kub zoo.

Koj siv lub ntsuas kub bimetallic li cas?

Siv Bimetallic Stemmed Thermometer
Cov ntsuas kub no feem ntau ntsuas qhov ntsuas kub ntawm 0º F txog 220º F. Txheeb xyuas cov qia hlau rau ib qho notch lossis me ntsis indentation raws li qhov qhia tau tias nyob deb npaum li cas rau hauv cov zaub mov tus pas ntsuas kub yuav tsum muab tso rau kom nyeem kom raug. Tsis txhob tso tus pas ntsuas kub hauv zaub mov thaum nws ua noj.

Calibrating Bimetallic Stemmed Thermometer

Tus pas ntsuas kub yog koj qhov kev tiv thaiv zoo tshaj plaws tiv thaiv kev kub ntxhov. Txawm li cas los xij, nws tsis muaj txiaj ntsig yog tias nws tsis ntsuas qhov ntsuas kub ntawm cov zaub mov kom raug. Koj yuav tsum ntsuas koj tus pas ntsuas kub txhua lub sijhawm koj tau siv rau hauv cov zaub mov kub heev rau txias heev, nws raug tso tseg, yog tias nws tsis tshwm sim tau nyeem qhov tseeb, thiab tsis tu ncua. Txoj kev yooj yim tshaj plaws los ntsuas tus ntsuas ntsuas kub yog los ntawm kev siv Txoj Kev Txias Point.

Freezing Point Method:

Muab cov kav hlau ntsuas qhov ntsuas kub tsawg kawg 2 ntiv tes, tsis txhob kov hauv qab lossis sab, rau hauv lub thawv ntim nrog cov dej khov thiab dej. Thaum lub koob kaw cia tsis txav mus rau tsawg kawg ib feeb, nyeem lub xov tooj. Nws yuav tsum nyeem 32º F. Yog hais tias nws tsis yog, ces, thaum tuav tus pas ntsuas kub nyob rau hauv dej khov, kho lub calibration txiv ntseej ntawm lub hauv paus ntawm lub dial kom txog thaum lub koob yog nyob rau ntawm 32º F. Tos lwm 15 vib nas this kom paub tseeb tias nws tuav ib tug. kub ntawm 32º F.

Bimetal Thermometer FAQ

 

 

Bimetal Thermometer

01. Dab tsi yog bimetallic stemmed tus pas ntsuas kub siv rau?

Tus pas ntsuas kub bimetal tuaj yeem ntsuas qhov ntsuas kub ntawm cov khoom noj tuab lossis sib sib zog nqus xws li nqaij nyug roasts thiab zaub mov hauv lub thawv ntim khoom.

02. Lub ntsuas kub bimetallic yog dab tsi?

Qhov tseeb ntawm tus pas ntsuas kub bimetal yog qhia raws li feem pua ​​(ntxiv lossis rho tawm) ntawm qhov ntsuas qhov siab tshaj plaws. Trerice Bimetal Thermometers yog ± 1. 3 qib A (tshwj tsis yog hom hnab tshos: ± 5.0% Full Scale, ASme B40. 3 qib 3).

03. Dab tsi yog txoj hauv kev zoo tshaj plaws los ntsuas cov ntsuas kub bimetallic?

Muab lub ntsuas cua sov los yog ntsuas rau hauv cov dej khov nab kuab. Xyuas kom qhov chaw hnov ​​​​tsw nyob hauv qab dej thiab tsis txhob kov ob sab ntawm lub thawv. Tos 30 vib nas this lossis kom txog thaum kev nyeem ntawv nyob ruaj khov. Kho lub thermometer yog li nws nyeem 32 degree F (0 degree).

04. Lub ntsuas kub hom twg yog qhov dav tshaj plaws hauv cov khoom noj?

Qhov cub-safe Bimetallic-coil Thermometers: Hom ntsuas kub no paub zoo rau cov neeg siv khoom feem ntau. Qhov no yog ib txwm "nqaij" tus pas ntsuas kub tsim los muab tso rau hauv cov zaub mov ua ntej nws nkag mus rau hauv qhov cub.

05. Koj tus pas ntsuas kub bimetallic yuav tsum tau ntsuas pes tsawg zaus?

Feem ntau, koj yuav tsum calibrate bimetal thermometers ua ntej txhua qhov hloov pauv. Calibrate cov ntsuas kub digital txhua lub lim tiam lossis hli. Ib txwm ntsuas cov ntsuas ntsuas kub tshiab lossis lub ntsuas ntsuas kub uas tau poob lawm. Nws kuj yog ib lub tswv yim zoo rau calibrate tus pas ntsuas kub tom qab siv nws los ntsuas qhov kub thiab txias sib txawv.

Peb paub zoo tias yog ib qho ntawm cov kws tshaj lij bimetal thermometer manufacturers thiab cov muag khoom hauv Suav teb, tshwj xeeb los ntawm cov khoom pheej yig thiab cov kev pabcuam zoo. Peb sov siab txais tos koj rau cov lag luam wholesale kev cai ua bimetal thermometer ntawm tus nqi sib tw los ntawm peb lub hoobkas.

(0/10)

clearall