Dab tsi yog Vortex Flow Meter?

Lub vortex meter yog ib hom volumetric flow meter uas ua rau siv lub ntuj phenomenon uas tshwm sim thaum cov kua ntws nyob ib ncig ntawm cov khoom bluff. Vortex flow meter ua haujlwm raws li txoj cai vortex shedding, qhov twg vortices (los yog eddies) yog los ntawm alternated downstream ntawm cov khoom. Qhov zaus ntawm lub vortex shedding yog ncaj qha proportional rau qhov tshaj tawm ntawm cov kua ntws los ntawm lub 'meter'.
Vortex flow meter yog qhov zoo tshaj plaws rau kev ntsuas ntsuas qhov kev taw qhia ntawm cov khoom txav mus los nthuav qhia cov teeb meem. Lawv muaj nyob rau hauv qib industrial, tooj dag, lossis tag nrho cov yas siv. rhiab heev rau variations nyob rau hauv cov txheej txheem tej yam kev mob yog tsawg thiab, tsis muaj txav qhov chaw, kuj tsis tshua muaj hnav piv rau lwm yam flowmeter.
Vortex flow meter muaj ntau yam zoo rau kev ntsuas ntws nrog rau kev teeb tsa yooj yim yam tsis muaj cov kab impulse, tsis muaj qhov txav txav los tswj lossis kho, tsis tshua muaj peev xwm ntws tawm, thiab qhov dav dav dav. Vortex meters kuj muaj kev siv hluav taws xob tsawg heev, tso cai rau siv rau hauv thaj chaw deb.
Tsis tas li ntawd, Vortex meters yog qhov tshwj xeeb uas lawv tuaj yeem ua kom haum rau cov kua dej, gasses, chav, thiab kev siv corrosive. Vortex flow meters kuj muaj peev xwm tiv taus cov txheej txheem siab thiab kub.
Vortex Flow Meter Styles
Ntse vortex meters muab lub teeb liab tso zis digital uas muaj cov ntaub ntawv ntau dua li qhov ntws xwb. Lub microprocessor nyob rau hauv lub flowmeter tuaj yeem kho tau rau qhov tsis txaus cov yeeb nkab ncaj qha, rau qhov sib txawv ntawm lub qhov taub thiab cov yeeb nkab mating, rau thermal expansion ntawm lub cev bluff, thiab rau K-factor hloov thaum Reynolds tus lej poob qis dua 10, { {2}}.
Cov khoom siv ntse ntse kuj tau muab nrog kev kuaj mob subroutines rau cov teeb liab cov khoom lossis lwm yam ua tsis tiav. Smart transmitters tuaj yeem pib sim cov txheej txheem los txheeb xyuas cov teeb meem nrog ob lub ntsuas thiab daim ntawv thov. Cov kev ntsuam xyuas ntawm qhov xav tau no tuaj yeem pab hauv ISO 9000 pov thawj.
Qee cov vortex flowmeters tuaj yeem ntes cov dej ntws ntau. Ib qho kev tsim qauv ntsuas ob qho tib si vortex zaus thiab lub zog vortex mem tes ib txhij. Los ntawm cov kev nyeem ntawv no, qhov ceev ntawm cov txheej txheem kua dej tuaj yeem txiav txim siab, thiab cov huab cua ntws tau suav tias yog nyob rau hauv 2% ntawm qhov ntev.
Lwm tus tsim yog muab nrog ntau lub sensors los xyuas tsis tau tsuas yog lub vortex zaus tab sis kuj kub thiab siab ntawm cov txheej txheem kua. Raws li cov ntaub ntawv no, nws txiav txim siab ob qho tib si qhov ceev thiab qhov loj txaus tus nqi. Qhov ntsuas no muaj 1.25% tus nqi raug thaum ntsuas qhov loj ntawm cov kua thiab 2% tus nqi raug rau cov pa roj thiab chav. Yog tias kev paub txog cov txheej txheem siab thiab qhov kub thiab txias yog qhov tseem ceeb rau lwm yam laj thawj, qhov ntsuas no muab qhov yooj yim, tsis tshua muaj nqi rau kev txhim kho cov transmitters cais.
Vortex Flow Meter Khoom Description
DN 15-DN200 Intelligent Gas Precession Vortex FlowmeterChav / roj ntws ntau: 80-800m3 / H. Khoom siv lub cev: 304 stainless hlau. Lub zog ua haujlwm: 24VDC lossis 12VDC. Kev ntsuas ntau: Gas: 7m / s ~ 4 0m / s; Ua kua: 0.7m / s ~ 7m / s.
Ntxiv rau Kev Nug
Ntxig Digital Vortex Flow Meter Cua Steam Flowmeterntsuas precision: kua: 1.0; gas: 1,5;. Khoom siv lub cev: 304 stainless hlau. Lub zog ua haujlwm: 24VDC lossis 12VDC. Kev ntsuas ntau: Gas: 7m / s ~ 4 0m / s; Ua kua: 0.7m / s ~ 7m / s.
Ntxiv rau Kev Nug
Clamp Vortex Gas Flow MeterRS485 Vortex Compressed Cua Flowmeter 4-20mA tso zis. Khoom siv lub cev: 304 stainless hlau. Lub zog ua haujlwm: 24VDC lossis 12VDC. Kev ntsuas ntau: Gas: 7m / s ~ 4 0m / s; Ua kua: 0.7m / s ~ 7m / s.
Ntxiv rau Kev Nug
Vortex High-precision Chav lossis Gas FlowmetersChav / roj ntws ntau: 80-800m3 / H. Khoom siv lub cev: 304 stainless hlau. Lub zog ua haujlwm: 24VDC lossis 12VDC. Kev ntsuas ntau: Gas: 7m / s ~ 4 0m / s; Ua kua: 0.7m / s ~ 7m / s.
Ntxiv rau Kev Nug
Vortex Flow Meter Rau Cov Kua Dejntsuas precision: kua: 1.0; gas: 1,5;. Khoom siv lub cev: 304 stainless hlau. Lub zog ua haujlwm: 24VDC lossis 12VDC. Kev ntsuas ntau: Gas: 7m / s ~ 4 0m / s; Ua kua: 0.7m / s ~ 7m / s.
Ntxiv rau Kev Nug
Hangzhou Yucheng Science & Technology Co., Ltd yog lub chaw tsim khoom ntawm cov cuab yeej siv siab, peb lub Hoobkas tau tsim nyob rau xyoo 2005 thiab tshwj xeeb hauv kev tsim cov ntsuas kub, ntsuas kub, ntsuas, thiab lwm yam khoom siv.
Tag nrho peb cov cuab yeej siv siab tau siv dav hauv Cov Roj & Roj refinery, textiles, tshuaj, zaub mov, thiab dej haus kev lag luam.
ISO9001: 2000 lub tuam txhab muaj ntawv pov thawj, los lav cov khoom zoo heev.
Cov neeg siv khoom tseem ceeb los ntawm Africa, South America, North America, thiab Asia. thiab Europe.
Peb lub peev xwm ntau lawm: txog 1 lab teeb ntawm ntau yam khoom siv siab.
Peb qhov chaw: Hoobkas hauv Ningbo thiab Hangzhou, chaw ua haujlwm hauv Hangzhou.
Tiv tauj peb rau txhua qhov kev thov. peb yuav tsim thiab tsim cov khoom zoo raws li koj qhov kev thov ntawm tus nqi sib tw.

01
Siab Zoo
02
Khoom siv Advanced
03
Pab neeg tshaj lij
04
Kev Pabcuam Kev Cai





Vortex Flow Meter Daim ntawv thov thiab kev txwv
Vortex meters feem ntau tsis pom zoo rau batching lossis lwm yam kev siv sib cuam tshuam. Qhov no yog vim qhov dribble flow rate teeb tsa ntawm qhov chaw nres tsheb batching tuaj yeem poob qis dua qhov ntsuas qhov tsawg kawg nkaus Reynolds tus lej txwv. Qhov me me ntawm tag nrho cov batch, qhov tseem ceeb tshaj qhov ua yuam kev tshwm sim yuav yog.
Low-pressure (low-density) gases tsis tsim kom muaj zog txaus siab pulse, tshwj xeeb tshaj yog cov kua velocities tsawg. Yog li ntawd, nws yuav zoo li tias nyob rau hauv cov kev pab cuam qhov rangeability ntawm lub 'meter' yuav tsis zoo, thiab qis ntws yuav tsis ntsuas. Ntawm qhov tod tes, yog tias txo qhov muaj peev xwm ua tau thiab qhov ntsuas tau raug qhov loj me rau cov dej ntws ib txwm muaj, vortex flowmeter tseem tuaj yeem txiav txim siab.
Yog tias cov txheej txheem cov kua dej zoo li lub tsho los yog tsim rau ntawm lub cev bluff, xws li hauv cov sludge thiab slurry kev pab cuam, qhov no nws thiaj li hloov qhov ntsuas K. Vortex-shedding flowmeters tsis pom zoo rau cov ntawv thov no. Yog hais tias, txawm li cas los xij, cov kua dej qias neeg tsuas muaj qhov nruab nrab ntawm cov khoom uas tsis yog txheej txheej, daim ntawv thov yuav ua tau. Qhov no tau tshwm sim los ntawm 2- xyoo sim ntawm limestone slurry. Thaum kawg ntawm qhov kev xeem, K qhov txiaj ntsig tau pom tias tau hloov pauv tsuas yog 0.3% los ntawm thawj lub Hoobkas calibration, txawm hais tias lub bluff lub cev thiab ntws raj tau ua phem caws pliav thiab pitted.
Thaum ntsuas ntau theem ntws (cov khoom hauv cov roj lossis cov kua; roj npuas hauv cov kua; cov kua dej hauv cov roj), qhov tseeb ntawm qhov ntsuas vortex yuav poob vim qhov ntsuas ntsuas tsis tuaj yeem sib txawv ntawm cov theem. Kev ntub dej tsis zoo yog ib daim ntawv thov zoo li no: cov theem ua kua yuav tsum tau ua kom sib npaug hauv cov chav, thiab cov kab ntsug ntws yuav tsum raug zam kom tsis txhob muaj kev sib tsoo. Thaum cov yeeb nkab yog kab rov tav, cov theem ua kua yuav tsum tau mus rau hauv qab ntawm cov yeeb nkab, thiab yog li ntawd lub puab cheeb tsam ntawm cov yeeb nkab yuav tsum tau qhib rau hauv qab. Qhov no tuaj yeem ua tiav los ntawm kev txhim kho lub cev bluff horizontally. Kev ntsuas qhov tsis raug hauv cov ntawv thov no yog kwv yees li 5% ntawm qhov tseeb ntws tab sis nrog kev rov ua tau zoo.
Qhov kev poob siab mus tas li los ntawm lub vortex meter yog ib nrab ntawm lub phaj orifice, kwv yees li ob lub taub hau tshaj tawm. (Ib lub taub hau tshaj tawm txhais tau tias yog V2 / g, qhov twg V yog qhov nrawm nrawm thiab g yog qhov gravitational tas li nyob rau hauv ib qho chaw sib xws.) Yog tias cov yeeb nkab thiab cov ntsuas ntsuas tau zoo thiab qhov loj me, qhov kev poob siab tsuas yog yuav tsum tau. ob peb psi. Txawm li cas los xij, kev txo qis (txhim kho qhov me me dua-kab-loj meter) txhawm rau txhawm rau txhawm rau Reynolds tuaj yeem ua rau lub taub hau poob ntau dua 10 psi. Ib qho yuav tsum tau ua kom paub tseeb tias lub siab vena contracta tsis poob qis dua lub vapor siab ntawm cov txheej txheem kua vim hais tias yuav ua rau cavitation. Lawm, yog hais tias lub backpressure ntawm lub 'meter' yog qis dua lub vapor siab, cov txheej txheem kua yuav flash, thiab lub meter nyeem ntawv yuav tsis muaj nuj nqis.
Vortex Flow Meter Khoom FAQ
Q: Lub vortex flow meter ua haujlwm li cas?
Q: Yuav ua li cas yog Yokogawa vortex flow meter?
Q: Vim li cas thiaj siv vortex flow meter?
Q: Dab tsi yog qhov txawv ntawm swirl flow meter thiab vortex flow meter?
Q: Puas yog vortex flow meter tib yam li qhov ntsuas huab cua?
Q: Dab tsi yog qhov siab poob ntawm lub vortex flowmeter?
Q: Dab tsi yog qhov siab tshaj plaws tshaj tawm ntawm vortex flow meter?
Q: Dab tsi yog qhov yuav tsum tau ua ncaj nraim rau lub vortex flow meter?
Q: Dab tsi yog qhov qis qis txiav tawm ntawm vortex flow meter?
Q: Hom chaw taws teeb yog dab tsi vortex flow meter?
Q: Dab tsi yog qhov tsawg tshaj plaws tshaj tawm rau vortex flow meter?
Q: Dab tsi yog qhov feem ntau siv flowmeter?
Q: Yuav ua li cas koj xam qhov ntws ntawm vortex?
Q: Lub neej expectancy ntawm flow meter yog dab tsi?
Peb paub zoo tias yog ib qho ntawm cov ua vortex flow meter manufacturers thiab lwm tus neeg nyob hauv Suav teb, tshwj xeeb los ntawm cov khoom pheej yig thiab cov kev pabcuam zoo. Peb sov siab txais tos koj rau cov lag luam wholesale kev cai ua vortex flow meter ntawm tus nqi sib tw los ntawm peb lub hoobkas.